AT-ETH-1553
- Portable Ethernet Device
- Based on 10/100 Ethernet for MIL-STD-1553 Applications
- Up to 2 Dual Redundant MIL-STD-1553 Channels
- Supported Configurations are:
> Stand-Alone BC
> Stand-Alone RT
> Stand-Alone MT - 16 User programmable DIO`s
- GPS Synchronization capability (optional)
- Externally Powered
- MIL-STD-1553 Programmable as Bus Controller or Remote Terminal or Monitor Terminal
- Direct Coupled or Transformer Coupled
- Sample Applications for Windows, Linux & RT-Linux available
The AT-ETH-1553 is an innovative product that provides “remoting” of 1553 operations on 10/100 Mbit/s Ethernet IP/UDP Local Area Network (LAN). The AT-ETH-1553 is a small, portable device that provides new levels of performance & flexibility for systems interfacing to a MIL-STD-1553 data bus. There are up to two dual redundant MIL-STD-1553 channels operating in BC, RT, MT & RT/MT modes. On board USB 2.0 port is also available for general purpose use. This module is the perfect COTS solution for MIL-STD-1553 data bus systems. Its small size, lightweight & durable construction makes it an ideal choice for use in avionics labs, field service, flight line test equipment & flight instrumentation applications. The Ethernet interface makes it suitable for use with desktop, laptop or tablet computers.
MIL-STD-1553 Channels
Each 1553 channel can emulate as a Bus Controller (BC), a Remote Terminal (RT) or a Bus Monitor (MT). Standard features include 64KB of RAM per 1553 channel, transformer & direct coupling, triggers, extensive BC & RT frame structures, RT Status Bit & Mode Code responses, along with advanced BC functionality. The advanced BC architecture provides a high degree of flexibility & autonomy by providing message schedule control, minimizing host overhead for asynchronous message insertion, facilitating bulk data transfers, double buffering, message retry, bus switching strategies, data logging & fault reporting. The RT architecture provides flexibility in meeting all common MIL-STD-1553B protocols. The choices of RT buffering & interrupt options provide robust support for synchronous & asynchronous messaging, while ensuring data sample consistency & supporting bulk data transfers. The interface includes a message monitor mode & a combined RT/MT mode where the MT will monitor all 1553 communications on the bus including the 1553 Channel’s assigned RT addresses. The Bus Monitor Mode provides for Selective Message Monitoring & Combined RT/Message Monitor Mode. Besides providing monitor filtering based on RT address, T/R bit & sub address, the message monitor eliminates the need to determine the start & end of messages by software. A combined RT/MT mode allows the device to run in both modes of operation at the same time on the bus.
Discrete I/O
The device includes 16 (digital 5V) discrete that are individually programmable as inputs or outputs (Open/Ground Discrete). The discrete outputs can be used for a variety of purposes, including triggering events, indicating status & general purpose use.
Stand-Alone Feature
AT-ETH-1553 module provides interface between non 1553 compatible device to 1553 bus system & this can be achieved through Ethernet interface. This feature allows the unit to operate in stand-alone mode in either BC or RT or MT. Firmware allows the User to dynamically reconfigure the unit to one of the supported modes.
SOFTWARE
The device comes with a powerful set of library functions to access the entire MIL-STD-1553B functionality. Sample applications will be provided to help users quickly setup & use the card. Sample programs for BC, RT, MT modes are included. Sample applications for Windows, Linux & RT-Linux are included.
System Interface
- 10/100 Mbps IEEE802.3 Standard Ethernet Interface
Ethernet
- RJ-45 Standard Ethernet connector
MIL-STD-1553B Interface
- Up to Two Dual Redundant MIL-STD-1553 Channels
- Transformer & Direct Coupled 1553 I/O
- 64KB RAM per 1553 Channel
- High Level 1553 C API Software Library Interface
- BC, RT, MT, RT/MT Operating Modes
1553 Bus Controller
- Minor & Major Frame Scheduling to Control Timing of 1553 Messages
- High & Low Priority Asynchronous Message Insertion
- Modify Messages or Data while BC is running
- Conditional Messages or Subroutines based on User Defined Conditions
- Multiple BC retry programmable options
- Automatic retries on alternate Bus
- Inter-message gap times up to 65.5ms
- Programmable response timeout up to 130us
- GPS synchronization of Bus Controller (optional)
1553 Remote Terminal
- Choice of Sub-address Single Message, Double Buffering, Circular Buffering or Global Circular Buffering
- Stack with Descriptors for Individual Messages
- Message Status, Time Tag, Command Word, Data Words
- Programmable Command Illegalization
- Programmable Busy by Sub-address
- Software-Programmable RT Address
- Busy Bit programmable by Sub address
- Alpha numeric Message ID
1553 Monitor Terminal
- Selective Message Monitor & Word Monitor
- Filter Based on RT Address, T/R bit, Sub-address Message Status, Time Tag, Command Word, Data Words
- Simultaneous RT/Message Monitor Option
- Dynamic Data Update
- Bus Error Status
- Bus Load
- Unique Message Identifier
- Message periodicity
- Record & Replay Option
- GPS synchronization (optional)
GPS Receiver (optional) for Synchronization
- GPS receiver on-board for synchronization
- Synchronization control through software
- Synchronization of on-board time tag counters with GPS time
- Separate GPS antenna provided along with the unit
USB Port
- One general purpose USB 2.0 port via Type B connector
Software Support
- Sample applications for Windows, Linux & RT-Linux included
Physical
- Durable Enclosure with covers for 1553 connectors
Environmental
- Operating temperature: 0° C to +50° C
- Storage temperature: -20° C to +70° C
Power
- +6V External Powered through Adaptor
Warranty
- 1 year limited warranty